P
AGE
23
of 28
A
UXILIARY
P
OWERED
ADA-C
OMPLIANT
E
MERGENCY
P
HONES
Pub.
42004-378A
d:\standard ioms - current release\42004 instr. manuals\42004-378a.doc
05/06
Hardware Settings Table
Default Settings
User Settings
Function
Setting
Jumper/Position
Setting
Jumper/Position
Auto-answer
Enabled
J14/3 & 2
Password Protection
Enabled
J9/3 & 2
Line Polarity
Non-polarized
J6/3 & 2
Programming Table
Function
Key Sequence
Default
Settings
User Settings
Auto-dial Programming
Emergency Button Auto-dial Number 1
DD
*1
*123456789*0#
Emergency Button Auto-dial Number 2
DD
*2
None
Emergency Button Auto-dial Number 3
DD
*3
None
Call Button Auto-dial Number
DD
*4
None
Primary Dial Tone Delay
#10
NN
Infinite
Secondary Line Dial Tone Delay
#11
NN
0 (zero) seconds
Ring-down Operation
*1
None
Password Programming
Password Protection
#14
NNNN
2468
Disconnect Programming
Emergency Push-button Disconnect
#17
L
01 (enabled)
Call Time-out Disconnect
#12
NN
10 minutes
Dial Tone Disconnect
#19
L
0 (disabled)
Other Programming Features
Silent Monitoring
#16
L
0 (disabled)
Ringing
#22
L
0 (disabled)
ADA Programming
ADA Options Enable
#18
L
#181
Identification Code Entry
#13
LNNN
None
Table Key
D = digit 0-9, *, or #
N = digit 0-9
L = 0-Disable, 1-Enable
T = 0-350 ms, 1-50 ms, 2-25 ms