I.

Safe Use Items

Design and manufacture of the instrument and testing achieves IEC61010 safety

standards (electronic measuring product safety requirements), this manual including the
safety of the instrument use and ensure the safety of equipment state, users must follow
the warnings and safety regulations Please read the following instructions before use.

Warning

● Instrument output voltage, before use, read and understand the instructions of
operational guidelines.
● Please take manual save you to check at any time.
● Must be instructed to use the instrument.
● Understand and comply with the safety operating instructions.
Must strictly abide by the above instructions.
If you don't comply, measurement may cause personal injury and equipment damage.

Dangerous (for improper operation can lead to serious or fatal damage)

● Before use, please wear insulated gloves.
● Please do not over AC/DC600V measurement circuit.
● Please do not test in flammable places, spark could cause an explosion.
● please do not hand wet or damp operators in instrument surface operation.
● Please don't charged the connection test line low.
● Low in the measurement, or do not touch the circuit being measured immediately after
the test, may result in electric shock accidents.
● Low test line or port found easy to damage the insulation properties of dirt or carbon
please stop test.

Warning (for improper operation exists the possibility of a severe or fatal damage)

● If the instrument is abnormal, please stop using it. For example: instrument damage or
bare metal parts.
● Please do not install in the device replacement parts or any unauthorized modification,
maintenance, please contact with me.
● Make sure all wires and instrument testing port connection is firm.

Note (for improper operation may cause personal injury or equipment damage)

Squared before measurement, confirm the voltage selection in the appropriate value.

If long time not to use, the battery should be fully charge, and recharge in 3 months.

Squared do not in high temperature, damp, places and condensation may be placed
under direct sunlight for a long time.

Please use a damp cloth or cleaner to clean the equipment enclosure, do not use
abrasives or solvents.

Instrument wet, please dry storage first.

Summary of Contents for HZJY-10K-I

Page 1: ...HZJY 10K I Insulation Resistance Tester Huazheng Electric Manufacturing Baoding Co Ltd...

Page 2: ...Contents I Safe Use Items 1 II Feature 2 III Specification Parameter 2 IV Introduction Of Instrument 3 V Instrument Using 6 VI Packing List 7...

Page 3: ...operators in instrument surface operation Please don t charged the connection test line low Low in the measurement or do not touch the circuit being measured immediately after the test may result in...

Page 4: ...al discharge when testing cables automatic rapid discharge of instruments 2 power supply modes the battery is powered by lithium ion battery and the battery life can reach 4 hours 10000V 100m test res...

Page 5: ...range 20uF Capacitance testing accuracy 15 0 03uF Capacitor discharge rate from 10000V to 10V 0 5S F Insulation resistance testing range and accuracy T 23 5 C RH 45 75 range accuracy 500V 1000V 2500V...

Page 6: ...Power Off No operation 3 minutes automatic shutdown H V Set test voltage 500V 1000V 2500V 5000V 10000V TIME SetThe test time 00 30 01 00 10 00 30 00 Switching software keys to a new function or from...

Page 7: ...1 key the power button until into the contrast adjustment menu 3 Press 1 or 2 keys to adjust contrast until the right 4 Press the 4 key save and exit if you don t need to adjust the press 3 key to ex...

Page 8: ...oltage and start 3 The instrument automatically record 15S 60S and 600S resistance and calculate the polarization index after 600 seconds Polarization index calculation method PI R600 R60 test connect...

Page 9: ...7 VI Packing List No Item Qty 1 Main engine 1 2 Power line 1 3 Black test line 1 4 Red test line 1 5 Green test line 1...

Reviews: