20
4. Save
To save the current discharged signal, You need to prepare a USB disk to store the
graphics.
Save Graphics: Press” SAVE/RECALL”, open the save/recall menu bar, press
“ graphic” F5 key to save, the discharge signals will be stored at the USB. After testing,
plug the USB at the PC, you can read the stored discharge signal waves at PC.
5. Close
After the testing, press” AUTORANGE” key to close automatic trigger till the key light is
off. After closing the automatic trigger, Press” Menu off” to close the menu bar if the
menu bar is
popping-up.
AUTORANGE Close
4.5 Two Channels testing
If use two channels for testing, you should connect two sensors. Open the two channels
simultaneously and setup respectively. The channel 1 is set as TEV, and channel 2 is
set as USS.
Two Channels setting screen
1. Connections
Composite TEV sensor connection
Use BNC-SMA cable, the BNC end is connected to main tester CH1 channel BNC port,
the SMA end is connected to the composite TEV sensor output port.
Ultrasonic sensor connection
Use BNC-SMA cable, the BNC end is connected to the main tester CH2 channel BNC