Acceptance Manual
Tecal RH2485 V2 Server
Part II Operation Guide
19
3.
Power off the server, and remove the power cables.
4.
Remove all the RAID 5 member disks in step 2 from the server, and install them
on another server that has the same configurations as the previous one. For
details about how to verify RAID properties, see case T01-0502.
5.
Power on the latter server in step 4. In the POST phase, press
F
and
Ctrl+H
as
prompted. In the
Adapter Selection
window, click
Start
.
6.
In the
MegaRAID BIOS Config Utility Foreign Configuration
window, click
Preview
. The
MegaRAID BIOS Config Utility Foreign Configuration
Preview
window is displayed.
7.
Click
Import
to import the original RAID 5 properties into the new server.
Expected Result
The
MegaRAID BIOS Config Utility Virtual Configuration
window is displayed, and
Spanned Drive Group:0, RAID 5
is displayed under
Logical View
on the right.
Test Description
This case uses RAID 5 properties supported by the LSI2208 as an example. You can
use the same method to verify other RAID levels. For details about how to configure
other RAID levels, see the related test cases.
T05-10 Verifying the Hot Swap Function for the Hard Disk Controller LSI SAS2308
T05-1001 Verifying the Hot Swap Function for the Hard Disk Controller LSI SAS2308
Objective
To verify the hot swap function for the LSI SAS2308
Test Networking
Diagram
None
Preset Conditions
1.
The server is powered on.
2.
You have configured RAID 1 properties by using two hard disks, synchronized
data between hard disks, and installed an OS.
Test Procedures
1.
Power on the server.
2.
After the OS starts, remove a RAID 1 member disk.
3.
Install a new hard disk of the same model, and check the hard disk indicator
state.
4.
Check the hard disk indicator state after a time period.
Expected Result
1.
In step 3, the yellow and green hard disk indicators blink at the same frequency,
which means that data is being synchronized between the two hard disks.
2.
In step 4, after data is synchronized for the new hard disk, the green indicator is
steady on, and the yellow indicator is off.
Test Description
The time period in step 4 ranges from half an hour to 8 hours, depending on the model
and capacity of the hard disk.
T05-11 Verifying the Hot Swap Function for the Hard Disk Controller LSI SAS2208