Item
Value
Supported disk types
SSD, SAS, NL-SAS
Supported hot-swappable interface
module types
l
8 Gbit/s Fibre Channel
l
GE
l
10GE (electrical)
l
SmartIO
ab
Maximum number of hot-swappable
interface modules per controller
2
Length of expansion SAS cables
Controller enclosure
l
Electrical cables: 1 m, 2 m, and 3 m
Disk enclosure
l
Electrical cables: 1 m, 2 m, 3 m, and 5 m
l
Optical cable: 15 m
High-density disk enclosure
l
Electrical cables: 5 m
For the high-density disk enclosure cascaded
to the controller enclosure: only 3 m (electrical
cable) is supported.
Redundancy degree of main components
l
Backup power module: 1 (per controller)
l
Power modules: 1+1
l
Fans: 1+1
a: SmartIO interface modules support various ports including 8 Gbit/s Fibre Channel ports,
16 Gbit/s Fibre Channel ports, 10 Gbit/s FCoE (VN2VF) ports, 10 Gbit/s Ethernet ports
(optical port, not negotiable to GE), and iWARP (interconnection between Scale-out
nodes). The V300R006C50 and later versions also provide the SmartIO interface modules
that support only 8 Gbit/s Fibre Channel ports.
b: In V300R006C60 and later versions, this interface module is used for front-end
interconnection. Each module has four optical ports and supports various port types. The
port types can be 8, 16, and 32 Gbit/s Fibre Channel, 10GE, and 25GE (not negotiable to
GE).
Port Specifications
Interface Module Type
Maximum Number of Ports per Interface
Module
4-port 8 Gbit/s Fibre Channel interface
module
Four ports for each front-end module
8-port 8 Gbit/s Fibre Channel interface
module
Eight ports for each front-end module
OceanStor 2600 V3
Product Description
6 Product Specifications
Issue 09 (2019-05-15)
Copyright © Huawei Technologies Co., Ltd.
117