ME60
Hardware Description
1 Hardware Description
Issue 01 (2018-05-07)
47
Item
Specification
4770 W (fully configured with BSUF-480s)
6520 W (fully configured with SFUI-1Ts)
Typical heat dissipation
13334.6 BTU/hour (fully configured with
BSUF-240s)
15475.9 BTU/hour (fully configured with
BSUF-480s)
21153.6 BTU/hour (fully configured with
SFUI-1Ts)
DC input voltage
input voltage range: –40 V to –72 V
input rated voltage: –48 V/ –60 V
AC input voltage
input voltage range: 180 V to 264 V
input rated voltage: 200 V to 240 V
MTBF
36.23 years
MTTR
0.5 hours
Availability
0.999998425
Slot quantity
12
Redundant MPUs
1:1
Redundant Switch fabrics
3+1
Redundant fans
[400G bundle] 2 assemblies in support for proper
fan operation in case of a single fan failure for a
short period at 40°C (104°F)
[1T bundle] 3 assemblies in support for proper fan
operation in case of a single fan failure for a short
period at 40°C (104°F)
Redundant power supply
[400G bundle] DC: 3+1
[400G bundle] HVDC&AC: 3+3
[1T bundle] DC: 5+1
[1T bundle] HVDC&AC: 4+4
Forwarding performance
2880 Mpps (BSUF-240)
Switching capacity
25.16 Tbps (SFUI-1T)
Operating temperature
Long-term: 0°C to 45°C (32°F to 113°F)