ME60
Hardware Description
1 Hardware Description
Issue 01 (2018-05-07)
46
Slot Name
Slot Quantity
Slot ID
Remarks
SRU
2
9 to 10
These slots hold
SRUs.
SFU
2
11 to 12
These slots hold
SFUs.
Interface Numbering
An interface is numbered in the format of slot number/subcard number/port number.
Slot number:
The slots of BSU/MSUs are numbered from top to bottom and from left to right (marked
on the panel), in the range of 1 to 8.
Subcard number:
The subcards are numbered from top to bottom and from left to right, starting from 0.
If an BSU/MSU does not have any subcard, the subcard number is 0.
Port number:
The ports are numbered from top to bottom and from left to right, starting from 0.
Technical Specifications
Item
Specification
Dimensions (H x W x D)
(21 U) 930 mm x 442 mm x 650 mm (36.61 in. x
17.40 in. x 25.59 in.) (Chassis main body)
(21 U) 930 mm x 442 mm x 750 mm (36.61 in. x
17.40 in. x 29.53 in.) (Dimensions of the chassis
body together with cable trays and front and back
attachments)
Weight (empty)
DC: 68.1 kg (150.16 lb) (without filler panels)
HVDC&AC: 63.7 kg (140.46 lb) (without filler
panels)
Weight (full configuration)
[400G bundle] DC:186.1 kg (410.35 lb)
[400G bundle] HVDC&AC:184.3 kg (406.38 lb)
[1T bundle] DC:209 kg (460.85 lb)
[1T bundle]HVDC&AC:206.5 kg (455.33 lb)
Cabinet installation standard
Can be installed in a standard 19" 800 mm-deep
cabinet. A Huawei 2.2 m-high N68E cabinet is used by
default.
Typical power consumption
4110 W (fully configured with BSUF-240s)