ME60
Hardware Description
1 Hardware Description
Issue 01 (2018-05-07)
35
Slot Name
Slot Quantity
Slot ID
Remarks
MPU
2
4 to 5
These slots hold
MPUs.
Interface Numbering
An interface is numbered in the format of slot number/card number/port number
Slot number:
The slots of BSU/MSUs are numbered from 1 to 3. The slot number increases from
bottom to top, facing the front panel of the ME60 (there are corresponding marks on the panel).
Card number:
The cards of BSU/MSUs are numbered from right to left and from bottom to top
beginning with 0. If there is no card on a board, the card number is set to 0.
Port number:
The ports of BSU/MSUs are numbered from top to bottom and from right to left
beginning with 0.
Technical Specifications
Item
Specification
Dimensions (H x W x D)
DC: (4 U) 175 mm x 442 mm x 650 mm (6.89 in. x
17.40 in. x 25.59 in.)
AC: (5 U) 220 mm x 442 mm x 650 mm (8.66 in. x
17.40 in. x 25.59 in.)
Weight (empty)
DC: 12 kg (26.46 lb)
AC: 20 kg (44.1 lb)
Weight (full configuration)
DC: 42 kg (92.61 lb)
AC: 52 kg (114.66 lb)
Cabinet installation standard
Can be installed in a standard 19" 800 mm-deep
cabinet. A Huawei 2.2 m-high N68E cabinet is used by
default.
Typical power consumption
DC: 800 W (fully configured with BSUF-51s)
AC: 950 W (fully configured with BSUF-51s)
DC: 920 W (fully configured with BSUF-100s)
AC: 1070 W (fully configured with BSUF-100s)
Typical heat dissipation
DC: 2595.5 BTU/hour (fully configured with
BSUF-51s)