l
The user connected to the POTS port that is enabled with caller emulation successfully
registers with the softswitch.
Context
The call emulation test verifies the basic calling services during service provisioning, and works
with the POTS line test to preliminarily locate a fault.
There are three types of call emulation tests: caller emulation test, callee emulation test, and
automatic emulation test. The call emulation test is irrelevant to protocols for the upstream
transmission. That is, it is applicable to SIP and H.248.
After the POTS port is configured with parameters for the caller emulation test and is enabled
with the caller emulation test, the offhook and dialing emulation can be performed on the POTS
port. If the called number is correct and the callee is free, the phone of the caller is ringing. After
picking up the phone, the callee hears his/her own voice.
Impact on the System
After a POTS port is enabled with the caller emulation test, services carried on the POTS port
are interrupted. These services will be recovered after caller emulation is complete.
Procedure
Step 1
In the
Physical Map
navigation tree on the
Main Topology
tab page, double-click the target
OLT, or select the target OLT, right-click, and choose
NE Explorer
.
Step 2
In the navigation tree, choose
GPON
>
GPON ONU
.
Step 3
On the
GPON ONU
tab page, set the search criteria to find the GPON ONU records.
Step 4
Select a required record from the ONT list, and then click the
The Ont's UNI Port Info
tab in
the lower pane.
Step 5
Select a record from the list whose
UNI Type
is
Pots
, right-click, and choose
Caller Emulation
Test
from the shortcut menu.
Step 6
In the dialog box that is displayed, set
Callee Number
, as shown in the following figure.
EchoLife HG8240/HG8245/HG8247 GPON Terminal
Service Manual
4 Maintenance and Troubleshooting
Issue 04 (2011-01-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.