40
Transition Point (ft
from water heater)
TEL of Standard 2”
Vent Pipe (ft)
TEL of Oversized 2”,
3”, or 4” Vent Pipe (ft)
Maximum TEL of all
Vent Pipe (ft)
15
30
95
125
20
40
77-1/2
117-1/2
25
50
60-1/2
110-1/2
30
60
43
103
35
70
26
96
40
80
8-1/2
88-1/2
None
85
0
85
Table 9 – TEL = Total Equivalent Length
F. EXHAUST AND INTAKE AIR VENT INSTALLATION
1. Use only solid PVC or CPVC pipe. FOAM CORE PIPING IS NOT APPROVED. Refer to Table 6 for
approved materials.
2. Remove all burrs and debris from joints and fittings.
3. All joints must be properly cleaned, primed, and cemented. Use only cement and primer approved for
use with the pipe material. Cement must conform to ASTM D2564 for PVC and ASTM F493 for CPVC
pipe.
All joints of positive pressure vent systems must be sealed completely to prevent leakage of flue products
into the living space.
4. Horizontal lengths of exhaust vent must slope towards the water heater not less than ¼” per ft to allow
condensate to drain from the vent pipe. If the exhaust pipe must be piped around an obstacle that results
in the creation of a low point, condensate will collect and form a blockage. This condensate must be
drained away using a field-installed condensate drain assembly (see Figure 26).
5. All piping must be fully supported. Use pipe hangers at a minimum of 4 ft intervals to prevent sagging
of the pipe where condensate may form.
6. Do not use the unit to support any piping.
7. A screened straight coupling is provided with the unit for use as an outside exhaust termination.
8. A screened inlet air tee is provided with the water heater to be used as an outside intake termination.
9. The following table lists optional intake air/exhaust vent terminations available from HTP.
VENT TERMINATION KITS
Description
Stock Code
2” PVC Concentric Vent Termination Kit
KGAVT0501CVT
3” PVC Concentric Vent Termination Kit
KGAVT0601CVT
2” Stainless Steel Vent Termination Kit
V500
3” Stainless Steel Vent Termination Kit
V1000
4” Stainless Steel Vent Termination Kit
V2000
Table 10
Summary of Contents for Versa Hydro PHE130-119
Page 23: ...23 Figure 5 Figure 6 ...
Page 24: ...24 Figure 7 ...
Page 25: ...25 F HYDRONIC PIPING Figure 8 ...
Page 26: ...26 Figure 9 ...
Page 27: ...27 Figure 10 ...
Page 28: ...28 Figure 11 ...
Page 29: ...29 Figure 12 ...
Page 32: ...32 F INTERNAL WIRING Figure 14 Internal connection diagram ...
Page 38: ...38 Figure 17 ...
Page 48: ...48 Figure 25 ...
Page 76: ...76 Figure 29 ...
Page 77: ...77 Figure 30 ...
Page 78: ...78 Figure 31 LP 314 G ...
Page 79: ...79 Figure 32 ...
Page 81: ...81 ...
Page 82: ...82 ...
Page 83: ...83 MAINTENANCE NOTES ...