User manual 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

                                                          

Summary of Contents for QUICKLAN6050N

Page 1: ... Copyright HT ITALIA 2017 Release EN 2 00 20 06 2017 ENGLISH User manual ...

Page 2: ... cable type 7 5 1 4 Setting cable length measuring unit 7 5 2 Test of cable mapping with RJ45 connector 8 5 2 1 Mapping test results 9 5 2 2 Description of errors of split pairs 11 5 2 3 Test with more remote units 11 5 3 Test of cable mapping with RJ11 connector 12 5 4 Test of Coax cable mapping with F connector 13 5 5 Measurement of cable length 14 5 5 1 Calibration of cable length 14 6 MAINTENA...

Page 3: ...CTIONS Before using the instrument please carefully read this user manual Each instruction preceded by symbol must be carefully complied with in order to prevent accidents or damage Make sure the batteries are installed correctly This instrument must be used only by skilled personnel capable of taking the appropriate safety precautions Do not carry out any measurement under conditions outside the ...

Page 4: ...ve been taken so that the instrument is delivered undamaged However we recommend generally checking the instrument in order to detect possible damage suffered during transport In case anomalies are found immediately contact the forwarding agent We also recommend checking that the packaging contains all components indicated in 7 4 1 In case of discrepancy please contact the Dealer In case the instr...

Page 5: ...tor for remote unit 14 Remote unit 1 for RJ11 and COAX cables 15 RJ11 connector for remote unit Fig 1 Description of the instrument 4 2 DESCRIPTION OF THE SYMBOLS SHOWN ON THE DISPLAY CAPTION 1 Test symbols Mapping Length 2 Test symbols Passed Error Split 3 Identifier ID remote unit 4 SET symbol 5 Low battery symbol 6 Auto Power Off APO symbol 7 Display with indication of measured Length and statu...

Page 6: ... to the Mapping test screen WIREMAP and to the Length measuring screen LENGTH Set the length measuring unit see 5 1 4 Define calibration operations of cable length see 5 5 1 4 3 4 SET UNIT key Press the SET UNIT key to select the current remote unit in case the test is performed with more remote units present see 5 2 3 Press and hold the SET UNIT key for 3s in order to enter exit the section for s...

Page 7: ...message On flashes and symbol appears on the display see Fig 3 right side 5 Press the TEST key to save setting and go back to main screen 5 1 2 Display backlight 1 Switch on the instrument by pressing the key 2 Press and hold the SET UNIT key for 3s The screen in Fig 3 left side appears on the display 3 Press the arrow keys or to go to the display s backlight setting The screen in Fig 4 left side ...

Page 8: ...ction of cable type Parameter CA5 flashes on the display 7 Press the arrow key or to select the cable type among the options CA5 CAT5 CA6 CAT6 AJII RJ11 COA COAX 8 Press the SET UNIT key to go to the selection of cable type with RJ45 connector Parameter StP flashes on the display 9 Press the arrow keys or to select the possible options StP shielded STP cable or UtP unshielded UTP cable 10 Press th...

Page 9: ...ent s input RJ45 connector see Fig 1 part 10 and to the remote unit 1 or if necessary use the patch cables provided as shown in Fig 7 Fig 7 Instrument connection through patch cables 5 Press the TEST key The instrument carries out the test according to the type of cable set displaying the message PASS for a correct test or symbol together with flashing pairs in case of wiring error see 5 2 1 6 Pre...

Page 10: ...age PASS on the display Correctly performed test on STP cable connected to remote unit 1 Symbol on the display OPEN PAIR Cables of the pair 4 5 interrupted Symbol on the display SHORT CIRCUITED CABLES Cable 1 of the pair 1 2 short circuited with cable 8 of pair 7 8 Cable 3 of the pair 3 6 short circuited with cables 4 and 5 of pair 4 5 Cables of the pair 4 5 short circuited ...

Page 11: ... 4 5 short circuited with cable 8 of pair 7 8 Screen S open Symbol on the display SPLIT PAIRS Correspondence pin to pin is maintained but the cables of pairs 3 6 and 4 5 are physically crossed CAUTION The instrument identifies the SPLIT error making the concerned pairs flash and showing symbol SPLIT on the display The error condition SPLIT is detected by the instrument only in case no other error ...

Page 12: ...airs 5 2 3 Test with more remote units The instrument allows carrying out mapping tests also on multiple cables by using other optional remote units and is capable of recognizing up to 4 remote units 1 Switch on the instrument by pressing the key 2 Select the category CAT5 CAT6 of the cables to be tested see 5 1 3 3 Select the type UTP STP of the cables with RJ45 connector to be tested see 5 1 3 4...

Page 13: ...onnection of the instrument to cable with RJ11 connector 4 Press the TEST key The instrument carries out the test and displays the message PASS for a correct test see Fig 11 or symbol together with flashing pairs in case of wiring error see 5 2 1 Fig 11 Display of correct test on cable with RJ11 connector 5 Press the L W key to display cable length see 5 5 CAUTION Connection of the remote unit is ...

Page 14: ...th F connector 4 Press the TEST key The instrument carries out the test and displays the message PASS for a correct test see Fig 13 left side or symbol together with flashing pairs in case of interrupted cable see Fig 13 right side Fig 13 Displaying the test on COAX cable with F connector 5 Press the L W key to display cable length see 5 5 CAUTION Connection of the remote unit is necessary in orde...

Page 15: ...e length measuring function 6 Press the TEST key to measure length with reference to pair 1 2 for RJ45 and RJ11 cables see Fig 14 left side or for COAX cables see Fig 14 right side Fig 14 Cable length measuring results 7 Press the arrow keys or to display the length of the remaining pairs 3 6 4 5 and 7 8 of the RJ45 cable being tested pairs 3 6 and 4 5 for RJ11 cables 5 5 1 Calibration of cable le...

Page 16: ...n order to respectively decrease or increase the value press and hold the keys for a quick selection 5 Press the SET UNIT key to select the activation deactivation of cable calibration Use the arrow keys or to select the options yes SI or no NO 6 Press the TEST key to save all settings and go back to main screen 7 Perform measurement as indicated in 5 5 Values will be considered by the instrument ...

Page 17: ...should perform this operation Before carrying out this operation make sure you have disconnected all cables from the input terminals Fig 16 Replacing internal batteries 1 Switch off the instrument and remove the cable from the input terminal 2 Lift the stand press the tag of the battery compartment cover to open it see Fig 16 3 Remove the batteries and replace them with new batteries of the same t...

Page 18: ... x 1in Remote unit weight 25g 1ounce Power supply Battery type 6x1 5V batteries type AAA LR03 Battery life 200 continuous tests Auto Power OFF after 15 minutes idling 7 3 ENVIRONMENT 7 3 1 Environmental conditions for use Reference temperature 5 C 40 C 41 F 104 F Allowable relative humidity 80 RH Storage temperature 10 C 60 C 14 F 140 F Storage humidity 70 RH Pollution level 2 This instrument comp...

Page 19: ... of interventions performed by unauthorized personnel Modifications to the instrument performed without the manufacturer s explicit authorization Use not provided for in the instrument s specifications or in the instruction manual The content of this manual cannot be reproduced in any form without the manufacturer s authorization Our products are patented and our trademarks are registered The manu...