26. At the end of test, based on the descriptions of previous
points, the message “STC Data available after Stop rec” is
displayed and then the results at OPC conditions are
displayed
15/05/10 15:34:26
V o c =
1 5 . 2
V
V m p p = 1 4 . 7
V
I m p p = 4 . 7
A
I s c =
5 . 2
A
P m a x = 2 0 0
W
F F =
7 7 . 1
%
I r r
=
- - - W / m
2
T c =
A u t o
Results @ OPC
Select
I - V
27. Press
ENTER
for the visualization of measurement results
both in numeric and graphical mode (§ 6.2.3)
28. Use the arrow key
for the selection of table or graph
visualization
29. Press
SAVE
key to store the result of test or
ESC/MENU
key to exit without saving and to go back to the main
screen
30. The “
Auto
” activation mode require to disconnect and
reconnect the test leads in order to start automatically a
new measurement
15/05/10 15:34:26
V o c =
1 5 . 2
V
V m p p = 1 4 . 7
V
I m p p = 4 . 7
A
I s c =
5 . 2
A
P m a x = 2 0 0
W
F F =
7 7 . 1
%
I r r
=
- - -
W / m
2
T a b l e
G r a p h
Select
I - V
31. At the end of I-V test, press the
ENTER
key, select the
“
Stop recording
” item and confirm with
ENTER
. The
messages “Wait…” and then “STC Data available in MEM”
are displayed
32. In this conditions, for the I-V tests performed with
irradiance values over the limit threshold and stable, the
correspondent STC results will be available inside memory
15/05/10 15:34:26
V d c
=
0 . 0
V
I r r
= - - - W / m 2
T c
= A u t o ° C
S t o p R e g .
S e t t i n g s
M e a s . T y p e
Select
I - V
33. The message “
Download data
” is displayed on the instrument and, at the same time,
the message “
Send
” is displayed on SOLAR-02 which means the transfer of irradiance
values and, if necessary, the module temperature values on the main unit
34. At the end of data transfer the instrument
automatically
join the average value of
irradiance (detected with IP = 5s) to each I-V test performed and, correspondingly, will
calculate the results translated to STC conditions and the Yes/No response for each
test. The complete results are recalled at display as described in § 7.3.2. See the §