![HT I-V400w User Manual Download Page 34](http://html1.mh-extra.com/html/ht/i-v400w/i-v400w_user-manual_2178116034.webp)
I-V400w - I-V500w - SOLAR I-Vw - SOLAR I-Ve
EN - 32
32. To stop testing, press the
GO/STOP
key on instrument
SOLAR I-Vw or SOLAR I-Ve and confirm pressing
ENTER
that you want to stop recording.
33. The display of SOLAR I-Vw or SOLAR I-Ve will show the
message “
DATA DOWNLOAD
” to indicate that the data will
be transferred to the main unit during its various phases.
34. After the automatic data transfer phase, the instrument:
Do not show any results if do not exist on the PV
installation a
“stable irradiance
” condition more than the
minimum irradiance threshold.
Display the best performance values if during the
recording, the Irradiance values reached the “
stable
”
condition and its values were higher than the minimum
irradiance threshold.
35. Press
SAVE
to save the results (see § 7.1) or
ESC
to exit
the screen of the results and go back to the initial screen.
15/05/10 15:35:00
P R p
0 . 8 1 5
I r r
9 7 1
W / m 2
P n o m 3 . 5 0 0
k W
T c
4 5 . 1
° C
T e
3 0 . 5
° C
P d c 3 . 1 2 5
k W
P a c 2 . 9 6 0
k W
n d c 0 . 8 0 6
n a c
0 . 9 4 7
A n a l y s i s R e s u l t
Select
E F F