HS Automatic ApS
Side 34 af 41
17-11-2005
HSAjet-CU user manual
Last saved
Fejl! Ukendt argument for parameter.
Connector Wiring
Connectors (start, encoder, etc) wiring.
Start sensor connections
As a start sensor, you can use a simple switch, or a photo cell.
PIN.......................................................... DESCRIPTION
1.............................................................. V I/O
2.............................................................. 5 V
3.............................................................. IN 2
4.............................................................. START
5.............................................................. GND
6.............................................................. IN 1
7.............................................................. 12 V
8.............................................................. OUT 1
9.............................................................. OUT 2
Using a
simple mechanical switch.
Loop pins 1-2 and connect the switch between
pins 4 and 5.
5 Volt NPN / PUSH/PULL sensor.
VCC to pins 1,2
Signal to pin 4
GND to pin 5
5 Volt PNP sensor.
VCC to pins 1,2
Signal to pin 4
GND to pin 5
1 K resistor between
pin 4 and 5
12 Volt NPN / PUSH/PULL
VCC to pins 1,7
Signal to pin 4