background image

VDP250MGD2

 

VELLEMAN 

c)  Mounting the Device 

 

 

Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms. 

 

The carrying construction must be able to support 10 times the weight of the device for 1 hour without deforming. 

 

The installation must always be secured with a secondary attachment e.g. a safety cable. 

 

Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified technician 

check the device once a year and once before you bring it into service. 

 

Install the device in a location with few passers-by that is inaccessible to unauthorised persons. 

 

Overhead mounting requires extensive experience: calculating workload limits, determining the installation 

material to be used… Have the material and the device itself checked regularly. Do not attempt to install the 

device yourself if you lack these qualifications as improper installation may result in injuries. 

 

Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws. 

 

Make sure there is no flammable material within a 0.5m radius of the device. 

 

Have a qualified electrician carry out the electric connection. 

 

Connect the device to the mains with the power plug. Do not connect it to a dimming pack. 

 

The installation has to be approved by an expert before the device is taken into service. 

 

6. Operation 

 

DMX512 Connection 

 

Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the male 3-

pin XLR input of the 

VDP250MGD2

. Multiple 

VDP250MGD2

s can be linked through serial linking. The linking cable 

should be a two-core screened cable with XLR input and output connectors. 

 

DMX-512 Chain with Termination 

 

A DMX terminator is recommended for installations where the DMX cable has to run a 

long distance or is in an electrically noisy environment (e.g. discos). The terminator 

prevents corruption of the digital control signal by electrical noise. The DMX terminator is 

simply an XLR plug with a 120

 resistor between pins 2 and 3, which is then plugged into 

the XLR output socket of the last device in the chain. 

Please see illustrations. 

 

Selecting the Start Address for the DMX Projector 

 

All DMX-controlled devices need a digital start address so that the correct device responds to the signals. This digital 

start address is the channel number from which the device starts to “listen” to the digital commands from the DMX 

controller. Enter the correct number and read it from the display located on the base of the 

VDP250MGD2

You can use the same starting address for a whole group of devices or enter an individual one for every device. 

When using one single address, all the units will “listen” to the control signal on one particular channel. In other 

words: changing the settings of one channel will affect all devices simultaneously. If you set different addresses, 

each device will “listen” to a separate channel number. Changing the settings of one channel will only affect the 

device in question. 

In the case of the 2-channel 

VDP250MGD2

, you will have to set the start address of the first device to 1, the second 

unit to 3 (1 + 2), the third to 5 (3 + 2), and so on. 

 

The LED next to the LED display indicates the status of the DMX signal: 

LED flashing: DMX signal present. 

LED off: No DMX input signal. 

 

After powering up the device, the display shows the DMX start address. Set the desired start address by means of 

the YES or NO button to increase or decrease the address value. Press ENTER to confirm. Other functions can also 

Summary of Contents for VDP250MGD2

Page 1: ...MULTICOLOUR GOBO 2 KANAALS MULTIKLEUREN GOBO MULTICOULEUR GOBO 2 CANAUX MULTIGOBO MULTICOLOR DE 2 CANALES 2 KANAL MULTICOLOUR GOBO USER MANUAL GEBRUIKERSHANDLEIDING NOTICE D EMPLOI MANUAL DEL USUARIO...

Page 2: ...VDP250MGD2 VELLEMAN 2...

Page 3: ...d Have a qualified person carry out the electric connection Make sure that the available voltage does not exceed the voltage stated in the specifications of this manual Do not crimp the power cord and...

Page 4: ...n the device is unplugged from the mains Let a lamp cool down before replacing it as the temperature of a lamp can reach 700 C during operation When handling a halogen lamp do not touch it with your b...

Page 5: ...nput and output connectors DMX 512 Chain with Termination A DMX terminator is recommended for installations where the DMX cable has to run a long distance or is in an electrically noisy environment e...

Page 6: ...64 69 Gobo 4 70 75 Gobo 5 76 81 Gobo 6 82 87 Gobo 7 88 93 Gobo 8 94 99 Gobo 9 100 105 Gobo 10 106 111 Gobo 11 112 117 Gobo 12 118 123 Gobo 13 124 129 Open shutter 130 135 Gobo 1 shake 136 141 Gobo 2 s...

Page 7: ...moist lint free cloth Do not use alcohol or solvents 7 There are no user serviceable parts except for the lamps and the fuse 8 Contact your dealer for spare parts if necessary 8 Technical Specificati...

Page 8: ...emene richtlijnen Dit toestel is ontworpen voor professioneel gebruik op podia in disco s enz U mag dit toestel enkel binnenshuis gebruiken en aansluiten op een wisselspanning van maximum 230VAC 50Hz...

Page 9: ...ouder onder de voedingsaansluiting achteraan het toestel 2 Verwijder de oude zekering en breng de nieuwe in 3 Plaats de zekeringhouder weer in de behuizing c Het toestel monteren Respecteer EN 60598 2...

Page 10: ...deraan uw VDP250MGD2 U kunt n enkel startadres gebruiken voor een groep toestellen of u kunt per toestel een nieuw startadres ingeven Wanneer u n enkel startadres instelt zullen alle toestellen luiste...

Page 11: ...55 Regenboogeffect traag snel 0 19 Geen rotatie 20 130 Rotatie met de wijzers van de klok mee traag snel 131 144 Geen rotatie Kanaal 2 Rotatierichting 145 255 Rotatie tegen de wijzers van de klok in t...

Page 12: ...allen tijde worden gewijzigd zonder voorafgaande kennisgeving VDP250MGD2 MULTICOULEUR GOBO 2 CANAUX 1 Introduction et caract ristiques Aux r sidents de l Union europ enne Des informations environnemen...

Page 13: ...garantie Garder votre VDP250MGD2 hors de la port e de personnes non qualifi es et de jeunes enfants 3 Directives g n rales Cet appareil a t d velopp pour usage professionnel dans des discoth ques des...

Page 14: ...technicien qualifi doit installer l appareil en respectant EN 60598 2 17 et toute autre norme applicable La construction portante de l appareil doit tre capable de supporter 10 x le poids de l appare...

Page 15: ...D terminez cette adresse avec les interrupteurs DIP au dos de l appareil Vous avez le choix entre une seule adresse de d part pour toute une s rie d appareils ou une adresse de d part par appareil Da...

Page 16: ...n 20 130 Rotation dans le sens des aiguilles d une montre lent rapide 131 144 Pas de rotation Canal 2 Direction de la rotation 145 255 Rotation dans le sens inverse des aiguilles d une montre lent rap...

Page 17: ...sent es dans cette notice peuvent tre modifi es sans notification pr alable VDP250MGD2 MULTIGOBO MULTICOLOR DE 2 CANALES 1 Introducci n Caracter sticas A los ciudadanos de la Uni n Europea Importante...

Page 18: ...por la garant a Mantenga el VDP250MGD2 lejos del alcance de personas no capacitadas y ni os 3 Normas generales Este aparato ha sido dise ado para un uso profesional en una discoteca un teatro etc Uti...

Page 19: ...ctiva EN 60598 2 17 y toda norma nacional antes de instalar el aparato La instalaci n debe ser realizada por un t cnico especializado El soporte donde ir el aparato debe ser capaz de sostener 10 veces...

Page 20: ...arato Es posible elegir entre una sola direcci n inicial para toda una serie de aparatos o una direcci n inicial por aparato Con una sola direcci n inicial para una serie de aparatos todos los aparato...

Page 21: ...rco iris lento r pido 0 19 Sin rotaci n 20 130 Rotaci n en el sentido de las agujas del reloj lento r pido 131 144 Sin rotaci n Canal 2 Direcci n de la rotaci n 145 255 Rotaci n en sentido contrario a...

Page 22: ...nwohner der Europ ischen Union Wichtige Umweltinformationen ber dieses Produkt Dieses Symbol auf dem Produkt oder der Verpackung zeigt an dass die Entsorgung dieses Produktes nach seinem Lebenszyklus...

Page 23: ...Ger t fern 3 Allgemeine Richtlinien Dieses Ger t ist eine Lichtsteuerung f r den professionellen Einsatz auf B hnen in Discotheken Theater usw Das Ger t ist nur zur Verwendung in Innenr umen und mit...

Page 24: ...eckdose auf der R ckplatte 2 Entfernen Sie die defekte Sicherung und setzen Sie eine neue Sicherung gleichen Typs ein 3 Bringen Sie den Sicherungshalter wieder in das Geh use ein c Das Ger t montieren...

Page 25: ...des VDP250MGD2 Sie k nnen mehrere Ger te auf eine einzelne Startadresse definieren oder Sie k nnen pro Ger t eine neue Startadresse eingeben Werden mehrere Ger te auf eine Startadresse definiert so fu...

Page 26: ...rbe Stroboskop 226 255 Regenbogen Effekt langsam schnell 0 19 keine Rotation 20 130 Rotation im Uhrzeigersinn langsam schnell 131 144 keine Rotation Kanal 2 Rotationsrichtung 145 255 Rotation gegen de...

Page 27: ...t warten 5 Trennen Sie das Ger t vom Netz ehe Sie mit den Servicearbeiten anfangen 6 Verwenden Sie zur Reinigung ein feuchtes fusselfreies Tuch Verwenden Sie auf keinen Fall Alkohol oder irgendwelche...

Reviews: