Use the original packaging if the device is to be transported. 

 

All modifications of the device are forbidden for safety reasons. 

 

Only use the device for its intended purpose. All other uses may lead to short circuits, burns, 

electroshocks, crash, etc. Using the device in an unauthorised way will void the warranty. 

4. Installation 

Refer to the illustration on page 2. 

nozzle  

mounting bracket 

housing  

tank cap 

a. Smoke 

Liquid

 

 

Only fill the tank when the device is unplugged from the mains. 

 

Use only non-inflammable smoke liquid without oil or grease. Any other liquid may damage the device 

and void the warranty. 

 

Only fill the tank with specially developed water-based smoke liquid: 

¾

 

VDLSL1

: 1 litre of standard smoke liquid 

¾

 

VDLSL5

: 5 litres of standard smoke liquid 

¾

 

VDLSL5H

: 5 litres of high density smoke liquid 

¾

 

VDLSLHT5

: 5 litres of professional high density smoke liquid 

 

Procedure: 

1. Make sure the device is switched off and disconnected from the mains. 

2. Unscrew the cap of the tank (figure above #4) on the top of the device. 

3. Carefully pour the smoke liquid in the tank. 

4. Reposition the cap and fasten it. 

Remark: Do not operate the device when the tank is open. 
b. Fuse

 

 

Only fit or replace a fuse when the device is unplugged from the mains. 

 

Replace a blown fuse with a fuse of the same type and rating (see “

Technical Specifications

”): 

1. Make sure the device is switched off and disconnected from the mains. 

2. Unscrew the fuse holder at the back with an appropriate screwdriver. 

3. Remove the old fuse and install a new one. 

4. Replace the fuse holder and fasten it with the screwdriver. 

c.  Mounting the Device

 

 

Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable 

norms. 

 

The construction to which the device is attached should be able to support 10 times the weight of the 

device for one hour without deformation. 

 

The installation must always be secured with a secondary attachment e.g. a safety cable (

VDLSC7

 / 

VDLSC8

). 

 

Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified 

technician check the device once a year and once before you bring it into service. 

 

Install the device in a location with few passers-by that is inaccessible to unauthorised persons. 

 

Overhead mounting requires extensive experience: calculating workload limits, determining the 

installation material to be used… Have the material and the device itself checked regularly. Do not 

attempt to install the device yourself if you lack these qualifications as improper installation may result 

in injuries. 

 

Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws. 

 

Make sure there is no flammable material within a 0.5m radius of the device. 

 

Have a qualified electrician carry out the electric connection. 

 

The installation has to be approved by an expert before the device is taken into service. 

5. Use

 

Make sure the power switch is set to OFF. Connect the device to the mains. Flick the power switch to ON. 

After a certain warm-up time (3 to 4 minutes), the device is ready to be used. 

Use the button on the remote control to select continuous smoke output. The stand-by lamp may be off 

and the smoke emission may stop even though you are holding the button – this means the device is 

heating up again and will be ready to operate in approximately 2 minutes. This process guarantees an 

optimum vaporization temperature and the best possible smoke emission. 

 

 

Summary of Contents for VDL500SMM

Page 1: ...OO MAC M Q NEB USER M GEBRU NOTICE MANUA BEDIEN L500S OKE MAC OKMACH CHINE QUINA D ELMASC MANUAL IKERSHAND E D EMPLOI AL DEL USUA NUNGSANLE SMM CHINE INE FUM E DE HUMO CHINE DLEIDING ARIO ITUNG O 1 1...

Page 2: ...VDL500SMM Rev 01 23 12 2010 Velleman nv 2...

Page 3: ...aut Please read the not damaged in t device stallation touch ng operation as rain and moistu e opening the ho ain guidelines in ity for any ensu and service this ately after it has g it switched off s...

Page 4: ...he Device Have the device installed by a qualified person respecting EN 60598 2 17 and all other applicable norms The construction to which the device is attached should be able to support 10 times th...

Page 5: ...ank with 1 3 of the bottle of cleaning liquid and let the machine run for several short periods Remove the remaining cleaning fluid from the tank and rinse the tank thoroughly with distilled water Do...

Page 6: ...leiding grondig v ransport Zo ja llatie raak geen nneer het in geb egen en vochtig stel niet aanges oor het negeren d afwijzen voor ouden door een u het toestel bes acht tot het toes klasse I wat wil...

Page 7: ...tel niet in werking wanneer de reservoirdop eraf is b Zekering U mag een zekering enkel plaatsen of vervangen wanneer het toestel niet is aangesloten op het lichtnet Vervang een gesprongen zekering do...

Page 8: ...r u aan onderhoudswerkzaamheden begint 6 Maak het toestel geregeld schoon met een vochtige niet pluizende doek Gebruik geen alcohol of solvent 7 De gebruiker mag geen onderdelen vervangen op de zekeri...

Page 9: ...ve tion toucher u squ il est en serv pluie et l humidi tation avant d o mmages surven esponsabilit po de l installation osition des va l appareil ait att otection I ce qu connexion lectr ser la tensio...

Page 10: ...ncien fusible et remplacez le 4 Remettez le porte fusible et serrez le avec le tournevis c Montage de l appareil Un technicien qualifi doit installer l appareil en respectant EN 60598 2 17 et toute au...

Page 11: ...rtain temps Quand l appareil est nettoy enlevez le liquide de nettoyage restant du r servoir et rincez le profond ment avec de l eau distill e N utilisez jamais de l eau r guli re pour nettoyer ou rin...

Page 12: ...se en contacto c dad n puede sufrir e su operaci n uvia o humedad entaci n de la re instrucciones de e de ning n da ben ser realizad xpuesto a grand iente protecci n I Po varla a cabo un no sea mayor...

Page 13: ...ebe ser realizada por un t cnico especializado El soporte donde ir el aparato debe ser capaz de sostener 10 veces el peso de ste durante una hora sin que se produzca una deformaci n de dicho soporte F...

Page 14: ...ca utilice agua normal para limpiar o enjuagar el aparato 7 Especificaciones alimentaci n m x 230VAC 50Hz consumo m x 500W fusible F 5A 250VAC 5 x 20mm referencia FF5N volumen de salida de humo 60m mi...

Page 15: ...so L500SMM Dies nem speziellen N pr fen Sie zuers und setzen Sie s nstallation Fas ktrischen Schlag als w hrend de Feuchtigkeit und ffnen vom Netz ng der Bedienu erende Folgesch autorisierten Fac n Be...

Page 16: ...kel wieder fest auf den Tank Bemerkung Schalten Sie das Ger t niemals ein ohne vorher den Tank geschlossen zu haben b Sicherung Trennen Sie das Ger t vor dem Sicherungswechsel von der Netzspannung Ers...

Page 17: ...Ger t vom Netz ehe Sie mit den Servicearbeiten anfangen 6 Verwenden Sie zur Reinigung ein feuchtes fusselfreies Tuch Verwenden Sie auf keinen Fall Alkohol oder irgendwelche L sungsmittel 7 Au er die S...

Page 18: ...toestel bv door oxidatie schokken val stof vuil vocht en door het toestel alsook zijn inhoud bv verlies van data vergoeding voor eventuele winstderving verbruiksgoederen onderdelen of hulpstukken die...

Page 19: ...manual del usuario y controle los cables las pilas etc antes de devolver el aparato Si no se encuentra un defecto en el art culo los gastos podr an correr a cargo del cliente Los gastos de transporte...

Reviews: