F09.19
V/f frequency of special motor 1 (F3)
F09.21 - 100.0 [100.0%]
F09.20
V/f voltage of special motor 1 (V3)
F09.22 - 100.0 [100.0%]
F09.21
V/f frequency of special motor 1 (F2)
F09.23 - F09.19 [40.0%]
F09.22
V/f voltage of special motor 1 (V2)
F09.24 - F09.20 [42.0%]
F09.23
V/f frequency of special motor 1 (F1)
0.0 - F09.21 [10.0%]
F09.24
V/f voltage of special motor 1 (V1)
0.0 - F09.22 [12.0%]
For special motor. Adopt user defined V/f curve in F09.19 - F09.24.
•
Refer to F09.01 - F09.06.
F09.25
Slip compensation gain of special motor 1 (low speed)
0.0 - 300.0 [0.0%]
F09.26
Slip compensation gain of special motor 1 (high speed)
0.0 - 300.0 [100.0%]
F09.27
Slip compensation switching frequency 1 of special motor 1
0.00 - F09.28 [5.00Hz]
F09.28
Slip compensation switching frequency 2 of special motor 1
F09.27 - F08.03 [10.00Hz]
F09.29
Slip compensation selection of special motor 1
00 - 11 [11]
Units: UP slip compensation selection
Tens: DN slip compensation selection
•
0: Set by F09.26.
•
1: Set by F09.25 - F09.26.
5.2.8
F10: Motor 1 Vector Control Speed-loop Parameters
Ref. code
Name Description
Setting Range [Default]
F10.00
Proportional gain 1 of motor 1 speed control
0.1 - 200.0 [10.0]
F10.01
Integral time 1 of motor 1 speed control
0.00 - 10.00 [0.10s]
F10.02
Proportional gain 2 of motor 1 speed control
0.1 - 200.0 [10.0]
F10.03
Integral time 2 of motor 1 speed control
0.00 - 10.00 [0.20s]
F10.04
Switching frequency 1 of motor 1 speed loop
0.00 - F10.05 [10.00Hz]
F10.05
Switching frequency 2 of motor 1 speed loop
F10.04 - 50.00 [15.00Hz]
F10.00 - F10.05,F10.07 set the PID parameter of speed regulator (ASR). The structure is shown in figure.
F09.25
F09.26
F09.27
F09.28
Output frequency
Slip compensation gain
Torque current setting
Frequency command
+
-
Frequency feedback
PID
Error
Torque limit