Chapter 5 Function Introduction
Shenzhen Hpmont Technology Co., Ltd.
―
30
―
HD3N-TC Series Inverter User Manual V1.0
Ref. code
Name Description
Setting Range [Default]
d00.50
Input terminal status
[Actual value]
Display input terminal status. Each bit (binary) of this parameter stands for different physical sources which
are in below table.
•
0: Input terminals disconnect with common terminals.
•
1: Input terminals connect with common terminals.
d00.50
Bit13
Bit12
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Frame3 / 4
AI2 AI1 DI6 DI5 DI4 DI3 DI2 DI1
Frame1 / 2
AI
DI4 DI3 DI2 DI1
123
d00.51
Output terminal status
[Actual value]
Display output terminal status. Each bit (binary) of this parameter stands for different physical sources
which are in the below table.
•
0: Output terminals disconnect with common terminals.
•
1: Output terminals connect with common terminals.
d00.51
Bit3
Bit2
Bit1
Bit0
Frame3 / 4
- RLY1
DO2
DO1
Frame1 / 2
RLY1
DO
123
d00.55
Total power up time (h)
[Actual value]
d00.56
Total running time (h)
[Actual value]
d00.61 Present
fault
[Actual value]
Display 100: means under-voltage.