Chapter 5 Function Introduction
Shenzhen Hpmont Technology Co., Ltd.
―
32
―
HD3N-TC Series Inverter User Manual V1.0
Ref. code
Name Description
Setting Range [Default]
F00.11
Command setting channel
0 - 2 [0]
0:
Keypad.
•
Start and stop inverter by pressing
button (
),
button (
) and
button (
).
1: Terminal. Start and stop by using corresponding external terminals.
•
DI terminal is set as FWD (DI=2), REV (DI= 3), JOGF1 (DI= 20), JOGR1 (DI=21) and JOGF2 (DI=22), refer to
group F15.
2: SCI. Start and stop by SCI port according to communication protocol.
F00.12
M key function
0 - 2 [2]
Note: Valid when LED keypad adopted only.
0: Switch running direction.
1: Switch local and remote control.
2: M key invalid.
F00.13
Starting frequency digital setting
0.00 - Upper limit frequency
[50.00Hz]
F00.10 = 0 or 1, F00.13 sets the initial frequency value.
F00.14
Frequency setting control
00 - 11 [00]
Units and tens are valid only when F00.10 = 0 or 1.
The current setting frequency value will be replaced by a new one when F00.13 has been changed.
Units: Save selection of frequency setting at power outage
•
0: Do not save at power outage.
•
1: Save at power outage.
Tens: Control selection of frequency setting at stop
•
0: Do not restore to F00.13 at stop.
•
1: Restore to F00.13 at stop.
F00.15
Jog running frequency digital setting
0.00 - Upper limit frequency
[5.00Hz]
F00.16
Interval of jog running
0.0 - 100.0 [0.0s]
After cancel jog command, inverter will not
respond to jog command within F00.16.
•
After the interval of jog is completed, it
immediately executes the arrived jog
command. As show in figure.
F00.17 Running
direction
0,1 [0]
0: The same as running command.
1: Opposite to running command.
F00.16
F00.15
Time
Time
Jog command
Acc
Dec
Frequency