Charging a Pb battery
The “Pb CHARGE” program is only suitable for charging Pb (lead acid) batteries with a nominal
voltage from 2-20v. Pb batteries can only deliver current lower in comparison to there capacity. The
same restriction applies to the charging process. Consequently, the optimum charge current can
only be set at 1/10th of the capacity. Pb batteries can not be fast charged. Please follow the
instructions from the manufacturer. The maximum capacity of the Pb battery should be 20Ah. Due
to the Characteristics of a Pb battery, the cut off point can be difficult to detect. We recommend that
a user set capacity cut off is used to protect the battery.
Charging a Pb (lead-acid) battery in charge mode
DEC INC
START
ENTER
BATT
STOP
This screen shows the real time status. Press START/ENTER to alter the
current and again to confirm the selection. The BATT.TYPE/STOP key
will stop the process at any time.
Pb-6
4.0A 12.59V
CHG
22:45
00682
Battery
Type
Charge
Current
Elapsed
Time
Charged
Capacity
Battery
Voltage
The charge current can be set on the left and the nominal voltage on
the right. Current range: 0.1-5.0A. The voltage should match the battery
being charged.
Press START/ENTER key for more than 3 seconds to start charging.
DEC INC
Pb CHARGE
12.0V(6P)
4.0A
>3 Seconds