15
Initial Parameter Setup (User Setup)
Capacity Cut-Off
ON
5000mAH
This program provides a maximum charge capacity protection function.
If the delta peak voltage can not be detected and the safety timer has
not cut in, the charge process will stop automatically when the battery
reaches the user set maximum charge capacity.
DEC INC
DEC
INC
When a charge process starts, the integrated safety timer starts to run.
If an error is detected or the delta peak circuit can not detect whether the
battery has fully charged or not, this program will prevent overcharging.
Safety Timer Calculation
When charging NiCd or NiMH batteries, divide the capacity of the pack
by the charge current, then divide the result by 11.9 Set this number as
minutes for the value in the safety timer menu. If the charger stopped at
this time about 140% of the capacity will have been fed into the battery.
Safety Timer
ON
120Min
For Example:
Capacity
Current
Safety Time
2000mAh
2.0A
(2000/2.0=1000)/11.9=84 Minutes
3300mAh
3.0A
(3300/3.0=1100)/11.9=92 Minutes
1000mAh
1.2A
(1000/1.2=833)/11.9=70 Minutes
DEC
INC
DEC
INC
DEC
INC
DEC
INC
Summary of Contents for reactor 500
Page 1: ......
Page 134: ...2015 ...