Procedure
1.
From the
Configuration
area, click
Expert Wizard
in the
Partitions
menu.
2.
Select the partition to be configured and then click
Next
until the wizard displays the
Select Control
Path Failover Type
screen.
3.
Select the type of control path failover for the partition and then click
Next
.
4.
Select the active and passive control path drives, and then click
Next
.
5.
In the example shown, drive 1 is set as the primary path and drive 2 is set as the secondary path.
6.
Click
Next
until the wizard displays the final screen.
7.
Verify the partition configuration and then click
Finish
.
8.
After the wizard reconfigures the partition, the library comes on line automatically.
9.
Modify switch zoning, if necessary, to enable host access to the library.
Locating the library world-wide node name after enabling basic control
path failure
When basic control path failover is enabled, the library is no longer presented as a logical unit behind the
tape drive and is assigned a new Fibre Channel node name.
The new world-wide node name is displayed on the
Status > Library Status
screen.
Verifying basic control path failover
There is always a library logical unit number hosted by a drive so the LUN indicator does not change
when basic control path failover is enabled.
Locating the library world-wide node name after enabling basic control path failure
33