Action
1.
To locate a message that indicates the location of the missing backup storage device, review the IML.
2.
Replace the failed backup storage device indicated by the IML.
For more information about replacing backup storage devices, see the server maintenance and
service guide on the Hewlett Packard Enterprise website (
http://www.hpe.com/info/proliantgen10-
).
Solution 3
Cause
Persistent memory backup power requirements exceed the available backup battery power.
Action
Remove any hardware that was recently added to the server.
For more information about removing components from your server, see the server maintenance and
service guide on the Hewlett Packard Enterprise website (
http://www.hpe.com/info/proliantgen10-
).
Solution 4
Cause
The backup power source was not sufficiently charged and the charging process was skipped by the user.
Action
Reboot the server and wait for the backup power source to sufficiently charge.
Solution 5
Cause
The backup power source was not sufficiently charged and the charging process timed out.
Action
1.
Review the IML for additional backup power source-related messages.
2.
Perform any actions indicated in the IML.
3.
If the issues still exist, replace the backup power source.
Unable to configure Scalable Persistent Memory
Cause
HPE Scalable Persistent Memory functionality is disabled because a physical NVDIMM-N is installed in
the server.
Action
Remove the physical NVDIMM-N from the server.
114
Unable to configure Scalable Persistent Memory