Persistent memory module
Persistent memory module relocation guidelines
relocation guidelines
Observe the relocation guidelines when doing the following:
When relocating persistent memory modules to another DIMM slot on the server.
When relocating persistent memory modules to another server.
When reinstalling persistent memory modules after replacing the server system board.
IMPORTANT:
IMPORTANT:
When data must be preserved, Hewlett Packard Enterprise strongly recommends that you perform a manual backup of
all user data on the persistent memory modules before changing the goal configuration or performing relocation
procedures.
Requirements for relocating
Requirements for relocating persistent memory modules
persistent memory modules or a set of
or a set of persistent memory modules
persistent memory modules when
when
the data must be preserved
the data must be preserved
The destination server hardware must match the original server hardware configuration.
All System Utilities settings in the destination server must match the original System Utilities settings in the original server.
If persistent memory modules are used with Persistent Memory Interleaving set to Enabled in the original server, do the following:
Install the persistent memory modules in the same DIMM slots in the destination server.
Install the entire interleaved set (all the DIMMs and persistent memory modules on the processor) on the destination server.
If any of the requirements cannot be met during relocation, do the following:
Manually back up the persistent memory data before relocating persistent memory modules to another server.
Relocate the persistent memory modules to another server.
Sanitize all persistent memory modules on the new server before using them.
Requirements for relocating encrypted
Requirements for relocating encrypted persistent memory modules
persistent memory modules or a set of
or a set of persistent memory
persistent memory
modules
modules when the data must be preserved
when the data must be preserved
If persistent memory modules are encrypted with local key management, either manually retrieve the persistent memory module
passwords from the server (user-generated passwords only) or export a password file to a USB key.
Hewlett Packard Enterprise recommends exporting the password file to a USB key.
Follow the requirements for relocating persistent memory modules or a set of persistent memory modules when the data must be
preserved.
Do one of the following:
If persistent memory modules are encrypted with local key management, either manually enter the persistent memory module
passwords in the System Utilities or import the password file from the USB key.
If persistent memory modules are encrypted with remote key management, enroll the HPE iLO in the key management server to
provide access to the data on the persistent memory modules.
For more information, see the Intel Optane persistent memory 100 series for HPE User Guide on the Hewlett Packard Enterprise
website (https://www.hpe.com/info/persistentmemory-docs
https://www.hpe.com/info/persistentmemory-docs).
Requirements for relocating
Requirements for relocating persistent memory modules
persistent memory modules or a set of
or a set of persistent memory modules
persistent memory modules when
when
the data does not have to be preserved
the data does not have to be preserved
Move the persistent memory modules to the new location and sanitize all persistent memory modules after installing them to the new
location.
Observe the DIMM and persistent memory module population guidelines.
Observe the process for removing a persistent memory module.
Observe the process for installing a persistent memory module.
Review and configure the system settings for Intel Optane persistent memory for HPE.
For more information, see the Intel Optane persistent memory 100 series for HPE User Guide on the Hewlett Packard Enterprise website
Persistent memory module relocation guidelines
162
Summary of Contents for ProLiant DL360
Page 8: ...10 6 Documentation feedback...
Page 9: ...Illustrated parts catalog Illustrated parts catalog 9...
Page 20: ...Processor spare parts Processor spare parts 20...
Page 40: ...Expansion board spare parts Expansion board spare parts 40...
Page 78: ...Customer self repair 78...
Page 79: ...Customer self repair 79...
Page 80: ...Customer self repair 80...
Page 81: ...Customer self repair 81...
Page 82: ...Removal and replacement procedures Removal and replacement procedures 82...
Page 96: ...Removing and replacing the bezel Removing and replacing the bezel 96...
Page 102: ...7 Secure the cables Removing and replacing the ball bearing rails 102...
Page 125: ...Removing the Pensando DSP DSC 25 2p SFP28 card with the iLO Sideband ALOM Module 125...
Page 159: ...guidelines Removing and replacing a persistent memory module 159...
Page 191: ...Troubleshooting Troubleshooting 191...
Page 193: ...Diagnostic tools Diagnostic tools 193...
Page 206: ...Component identification Component identification 206...
Page 236: ...Smart Carrier NVMe SCN drive LED definitions 236...
Page 238: ...HPE Basic Drive LED definitions 238...
Page 241: ...BIOS Platform Configuration RBSU Hot plug fans 241...
Page 248: ...Cabling Cabling 248...
Page 253: ...SFF backplane to P824i p controller 253...
Page 255: ...2 SFF backplane to P816i a controller 2 SFF backplane to P816i a controller 255...
Page 256: ...10 SFF NVMe backplane to NVMe riser 10 SFF NVMe backplane to NVMe riser 256...
Page 257: ...2 SFF NVMe backplane to primary riser 2 SFF NVMe backplane to primary riser 257...
Page 258: ...1 SFF rear backplane to system board SATA 1 SFF rear backplane to system board SATA 258...
Page 259: ...10 SFF backplane to P408i a controller 10 SFF backplane to P408i a controller 259...
Page 263: ...4 LFF backplane to P408i a controller 4 LFF backplane to P408i a controller 263...
Page 265: ...Specifications Specifications 265...
Page 277: ...Support and other resources Support and other resources 277...