Chapter 4
Understanding Error States 127
Chapter 4
Use the following steps to resolve the problem:
1. From the screen with the initial error message or from the
Hard Error
Log
,
select
[More]
to retrieve more information about the error.
2. Record all information from this screen for later reference.
3. Select
[More].
Record the list of recommendations on this and any
subsequent screens. To retrieve this information after you exit, view the
latest entry in the hard error log.
4. Perform the recommendations in the order presented. Continue with each
successive recommendation until the problem is isolated. Here are some
examples of the types of recommendations:
— Power cycle the library.
— Remove a tape from the library.
— Check the library or host configuration.
— Check the cable connections (data or power).
— Run front panel diagnostic tests.
— Reposition a tape or magazine.
Caution
Before upgrading firmware, be sure to generate a support ticket
using HP Library & Tape Tools (see
page 154
). The resulting
information may be helpful to your service representative in
resolving potential issues that may have prompted the firmware
upgrade.
— Upgrade firmware.
5. If the problem persists after implementing all of the recommendations
presented on the front panel display, contact your service representative.
(See
page 195
.)
Summary of Contents for Surestore E Tape Library Model 2/20
Page 1: ...hp surestore tape library 2 20 4 40 6 60 8 80 and 10 100 series user s guide ...
Page 2: ......
Page 6: ...4 Updates hp surestore tape library ...
Page 12: ...10 ...
Page 116: ...114 Retrieving Library Information Chapter 3 ...
Page 182: ...180 Upgrading Firmware Chapter 5 ...
Page 222: ...220 Library Error Codes Appendix ...
Page 236: ...234 ...
Page 237: ......