4–22
MSL5000 Series Library User Guide
Operation
Sequential Mode
Selecting a sequential mode (using Library Mode) enables
the library robotics to unload a full tape cartridge (or at the
end of data), select, load the next tape cartridge from the
appropriate magazine, and then automatically continue
read/write operations without software intervention. Two
options are available: Normal and Recirculate.
LCD Contrast Adjust
The LCD contrast controls let you increase or decrease the
contrast of the LCD display. The incremental steps are set by
adjusting the LCD Contrast Adjust option from the Library
option. Incremental steps can range from 0 to 31 depending
on your preference. The default is 16.
Mail Slot Mode
Lets you enable or disable the mail slot(s) in a library. For the
MSL5026/MSL5030, the default is Mail Slot Enabled. For the
MSL5052/MSL5060, the default is Both Mail Slots Enabled.
Barcode Label Size
Lets you limit the length of the barcode label. Possible
settings are 1 through 8. The default is 8.
Barcode Label Assignment
Lets you specify the alignment of a bar code label. The
options are Left or Right. When used in conjunction with the
label size option, this option strips unwanted trailing
characters (left alignment) or leading characters (right
alignment). The default is Left Align.
Barcode Label Check Digit
Lets you specify whether to enable or disable the verification
of a check digit character in the barcode label. The default is
Disabled.
Barcode Reader
Lets you enable or disable the barcode reader retries option.
The default is Retries Enabled.
Module Configuration
Lets you configure a library for standalone, master, or slave
operation. The default is Standalone.
Table 4–2: View Library Options (Continued)
Option
Description