90
Informational
The partner controller does not have a
mirrored configuration image for the
current controller, so the current
controller’s local flash configuration
is being used. This event is expected
if the other controller is new or its
configuration has been cleared.
95
Critical
Both controllers in an active-active
configuration have the same serial
number. Non-unique serial numbers
can cause system problems; for
example, vdisk ownership and
WWNs are determined by serial
number.
A service technician must examine
both controller serial numbers and
change at least one of them.
96
Informational
Pending configuration changes that
take effect at startup were ignored
because customer data might be
present in cache.
If the requested configuration
changes did not occur, make the
changes again and then use a user-
interface command to shut down or
restart the controller.
100
Informational
During active-active operation, an
event (potential error) occurred while
communicating with the EMP, which
reports SES data.
101
Informational
An update of EMP data has been
triggered. This event is for internal
use only.
103
Informational
Volume name change is complete.
104
Informational
Volume size change is complete.
105
Informational
Volume LUN change is complete.
106
Informational
A volume has been added.