60
Informational
A disk channel was reset from
another initiator or target.
61
Critical
A serious error, which might indicate
hardware failure, occurred while
communicating on the specified disk
channel. The controller will attempt
to recover.
• If the controller recovers, no
action is required.
• View other logged events to
determine other action to take.
62
Informational
A spare drive has failed.
Replace the failed drive.
65
Critical
An uncorrectable ECC error occurred
on the buffer memory on startup. The
controller is automatically restarted
and—if it was operating in active-
active mode (i.e., independent cache
performance mode was disabled)—its
cache data is restored from the
partner controller’s cache.
67
Informational
The controller has identified a new
disk drive or group of disk drives that
constitute a vdisk and has taken
ownership of the vdisk. This can
happen when disk drives containing
data have been inserted from another
enclosure.
68
Informational
Controller is in a shut-down state.
69
Critical
Enclosure reported a general failure.
Check the controller module or
expansion module for problems
such as not being fully inserted,
and for bad cables.
71
Informational
The controller has started or
completed failing over.
72
Informational
(Active-active environment)
After failover, recovery has started or
has completed.