39
Warning
The sensors monitored a temperature
or voltage in the warning range.
• Check that the storage system’s
fans are running.
• Check that the ambient
temperature is not too warm. The
enclosure operating range is
41 F to 104 F (5 C to 40 C).
• Check for any obstructions to the
airflow.
• If none of the above explanations
apply, replace the controller FRU
that reported the error.
When the problem is fixed, event
47 is logged.
40
Critical
The sensors monitored a temperature
or voltage in the failure range.
• Check that the storage system’s
fans are running.
• Check that the ambient
temperature is not too warm. The
enclosure operating range is
41 F to 104 F (5 C to 40 C).
• Check for any obstructions to the
airflow.
• If none of the above explanations
apply, replace the controller FRU
that reported the error.
When the problem is fixed, event
47 is logged.
41
Informational
A vdisk spare has been added.
43
Informational
A vdisk has been deleted.
44
Warning
The controller contains dirty cache
data for the specified volume but the
corresponding disk drives are not
online.
• Determine the reason that the
drives are not online.
• If an enclosure is down,
determine corrective action.
• If the virtual disk is no longer
needed, you can clear the orphan
data; this will result in lost data.