6
Informational
or warning
Vdisk creation status. This event is
logged as informational if creation
immediately failed, was canceled by
the user, or succeeded. This event is
logged as a warning if creation failed
during initialization.
8
Warning
A drive in a vdisk failed and the
vdisk changed to a critical or offline
state. If a spare is present the
controller automatically uses the
space to reconstruct the vdisk.
• See “Disk Drive Errors and
Recommended Actions” on
page 300.
• If dynamic spares is enabled,
replace the failed drive. The
system automatically
reconstructs the vdisk.
• If dynamic spares is disabled and
no spare is available, replace the
failed drive and add it as a vdisk
spare to the critical vdisk.
9
Informational
A spare disk drive has been used in a
critical vdisk to bring the vdisk back
to a fault-tolerant state. Vdisk
reconstruction starts automatically.
16
Informational
A global spare has been added.
18
Informational
or warning
Vdisk reconstruction status. This
event is logged as informational if
reconstruction succeeded, or as a
warning if reconstruction failed.
19
Informational
A rescan has completed.
20
Informational
A firmware update has completed.
21
Informational
or warning
Vdisk verification has completed.
This event is logged as informational
if the command fails immediately,
succeeds, or is aborted by the user; or
a warning if the operation fails during
verification.
23
Informational
Vdisk creation has started.