LED Indicators, Switches, and Jumpers
Redundant ROM Settings
IMPORTANT: Switching ROM images can also be done through RBSU. Use the following
procedures when RBSU is inaccessible. For information on accessing redundant ROM options
through RBSU, as well as disaster recovery procedures, refer to Chapter 5, “Server
Configuration and Utilities.”
To switch from the current ROM to the backup ROM:
1.
Power down the server.
2.
Set the system configuration switch positions 1, 5, and 6 to the On position.
3.
Power up the server. The ROM will beep and halt when the ROM images have
been swapped.
4.
Power down the server and reset all system configuration switch positions to the
default Off position.
5.
Power up the server.
If both the current and previous versions of the ROM are corrupted, refer to
“Automatic Server Recovery” in Chapter 5.