Server Component Identification
iLO/Redundant ROM Override Switch (SW5)
The iLO/ Redundant ROM Override switch (SW5) is a two-position switch that is used for
miscellaneous purposes. The iLO security override switch allows the administrator full access
to the iLO processor. This access is necessary if the administrator lost their password or if the
iLO boot-block needs to be flashed.
Figure 4-15: iLO/ Redundant ROM Override switch (SW5)
Table 4-16: iLO/ Redundant ROM Override Switch (SW5)
Position Default Function Description
Settings
1 Off
iLO
security
override
The override allows the
administrator full access to
the iLO processor.
Open (off)
Normal
Closed (on)
Override
2 Off
Redundant
bootblock
select
Forces booting from the
redundant bootblock
Open (off)
Normal
Closed (on)
Redundant bootblock (ROM)
4-20
HP ProLiant DL585 Server Maintenance and Service Guide
Summary of Contents for ProLiant DL585