Removal and Replacement Procedures
SCSI Backplane
To remove the SCSI backplane:
1. Extend the server from the rack. Refer to “Extending the Server from the Rack” earlier in
this chapter.
2. Power down the server. Refer to “Powering Down the Server” ea rlier in this chapter.
3. Unseat all the hot-plug SCSI hard drives and pull them away from the SCSI backplane.
Refer to “Hot -Plug SCSI Hard Drives” earlier in this chapter.
NOTE: If you plan to take the hard drives out of the drive cage, label them so that they will be
installed in the same slot.
4. Remove the access panel. Refer to “R emoving the Access Panel” earlier in this chapter.
5. Disconnect any SCSI cables from the SCSI backplane. Refer to “S CSI Cables” earlier in
this chapter.
6. Loosen the thumbscrew (1).
7. Remove the SCSI backplane from the chassis (2).
Figure 2-34: Removing the SCSI backplane
Reverse the steps to replace the SCSI backplane.