Server Component Identification
Table 4-6: QuickFind Diagnostic Display LEDs
continued
Item Description
Status
Action
5 Temperature
Off
=
normal
On = attention required
One or more components have experienced an elevated
temperature or a thermal shutdown.
A thermal shutdown is indicated by the Therm Trip LED.
•
Be sure the processor heatsink is properly attached.
•
Be sure there are no 1.7-inch DIMMs installed that
prevent airflow across the processor heatsink).
•
Be sure the correct DIMMs (1.2 inches tall) are
installed.
•
Be sure that all fans are installed and working
properly.
•
Be sure that the server environment meets posted
requirements.
For information about server environment requirements
refer to the HP ProLiant DL585 Server User Guide on the
documentation CD or at
www.hp.com/support
.
6 DIMM
Off
=
normal
On = attention required
DIMM failure or configuration error. Refer to the IML or
POST messages.
7
I/O power fault
Off = normal
On = attention required
A power fault on the system I/O board occurred. If
problem persists, replace the system I/O board.
8
Therm trip
Off = normal
On = attention required
The server experienced a thermal shutdown.
If one of the CPU thermal LEDs is amber, that CPU
experienced an overtemperature condition.
•
Be sure that the processor heatsink is properly
attached. For more information, refer to Chapter 5,
“Troubleshooting.”
•
Be sure there are no 1.7-inch DIMMs installed that
prevent airflow across the processor heatsink).
•
Be sure the correct DIMMs (1.2 inches tall) are
installed.
•
Be sure all fans are installed and working properly.
9
SCSI interlock
Off = normal
On = attention required
Be sure the SCSI backplane is installed properly.
10
Power supply 1
Off = normal
On = attention required
Look at the LEDs on the front of the power supply and
take the appropriate action.
11
Power supply 2
Off = normal
On = attention required
Look at the LEDs on the front of the power supply and
take the appropriate action.
4-8
HP ProLiant DL585 Server Maintenance and Service Guide