Server component identification 17
When the boot device selector switch is set to FLP TOP, the optical drive in the bottom bay is designated
as the primary optical drive. The diskette drive in the top bay is bootable. The server cannot boot from a
diskette drive in the bottom bay when the boot device selector switch is set to FLP TOP.
When the boot device selector switch is set to FLP BOT, the optical drive in the top bay is designated as
the primary optical drive. The diskette drive in the bottom bay is bootable. The server cannot boot from a
diskette drive in the top bay when the boot device selector switch is set to FLP BOT.
NOTE:
If two optical drives are installed in the server, the server will first attempt to boot from
the primary optical drive ("
Boot device selector switch
" on page
16
). The boot device selector
switch setting determines which drive is the primary optical drive.
Switch setting Description
FLP TOP (default) Diskette drive in top bay is bootable
Primary optical drive in bottom bay is bootable
FLP BOT
Primary optical drive in top bay is bootable
Diskette drive in bottom bay is bootable
Systems Insight Display LEDs
The front panel health LEDs indicate only the current hardware status. In some situations, HP SIM might
report server status differently than the health LEDs because the software tracks more system attributes.
The amber Systems Insight Display LEDs are located on the media board. In normal operations, all of the
LEDs are off unless one of the components fails.
NOTE:
The system management driver must be installed for the internal health LED to provide
pre-failure and warranty conditions.