Operations 22
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
To prevent damage to electrical components, take the appropriate anti-static
precautions before beginning any installation, removal, or replacement procedure. Improper
grounding can cause electrostatic discharge.
CAUTION:
Do not operate the server for long periods with the access panel open or removed.
Operating the server in this manner results in improper airflow and improper cooling that can
lead to thermal damage.
1.
Power down the server (on page
17
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
17
).
o
Remove the server from the rack (on page
20
).
4.
Open the access panel latch, slide the access panel to the rear of the chassis, and then remove the
access panel.
If the access panel latch is locked, use a T-15 Torx screwdriver to unlock the latch.
Install the access panel
1.
Place the access panel on top of the server with the access panel latch open. Allow the panel to extend
past the rear of the server by approximately 1.25 cm (0.5 inch).
2.
Close the access panel latch. The access panel slides to a closed position.
3.
Use a T-15 Torx screwdriver to tighten the access panel latch screw.
Summary of Contents for ProLiant DL160 Gen9
Page 92: ...Cabling 92 M 2 SSD cabling Slot 1 cable routing Slot 2 cable routing ...
Page 94: ...Cabling 94 FBWC module slot 2 cabling FBWC module slot 3 cabling ...
Page 95: ...Cabling 95 HP Smart Storage Battery cabling FlexibleLOM cabling ...
Page 99: ...Cabling 99 Front USB 3 0 cabling ...
Page 129: ...Support and other resources 129 ...
Page 130: ...Support and other resources 130 ...