Operations 21
If the access panel latch is locked, use a T-15 Torx screwdriver to unlock the latch.
Install the access panel
1.
Place the access panel on top of the server with the access panel latch open. Allow the panel to extend
past the rear of the server by approximately 1.25 cm (0.5 inch).
2.
Close the access panel latch. The access panel slides to a closed position.
3.
Use a T-15 Torx screwdriver to tighten the access panel latch screw.
Remove the air baffle
CAUTION:
For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
To remove the component:
1.
Power down the server (on page
17
).
2.
If you are performing a non-hot-plug procedure, remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
17
).
o
Remove the server from the rack (on page
19
).
4.
Remove the access panel (on page
20
).