4-5
Planning and Implementation for the 2600-PWR Switches
Planning the PoE Configuration
P
lann
ing and
Implemen
ta
tion for the 2600-
PWR Sw
itc
h
e
s
■
When two switches are connected to the 600 RPS/EPS ports, the PoE
power available to each switch is a maximum of 204 W. If all of your PDs
consume on average less than 7.5 W each (allowing for any line loss) then
all 24 ports will receive redundant power should a switch’s internal PoE
power supply fail.
Redundant power is available as long as the total power required remains
below 204 W.
Source of
Power
Watts
Available
# of Ports Powered and
Average watts/Port
Redundant # of Ports
Powered and Average watts/
Port
Internal PoE
Power Supply
406
24 @ average 15.4 W each None
Internal plus
External PoE
Power Supply
406 + 204
1 - 24
24 @ average 15.4 W each 24 @ 7.5 W each
12 @ 15.4 W each
External PoE
Power Supply
(Failed Internal
PoE Power
Supply)
204
24 @ 7.5 W each
12 @ 15.4 W each
None