5-8
Planning and Implementation for the 2610-PWR Switches
Planning Your PoE Configuration
Pl
a
nni
n
g
a
nd
Imp
le
m
entatio
n fo
r th
e 2610
-
P
W
R Sw
it
c
hes
Figure 5-5. Example of an 600 RPS/EPS Powering Two 2610-48-PWR Switches
The lowest loaded bank of ports (1-24 or 25-48) has 22 W reserved and is
‘bank 2’ in the table above.
600 RPS/EPS
ProCurve Switch
2610-48-PWR
Source of
Power
Watts
Available
# of Ports Powered and
Average watts/Port
Redundant # of Ports
Powered and Average watts/
Port
Internal PoE
Power
Supply
406
24 @ average 15.4 W each
48 @ average 7.5 W each
None
Internal plus
External PoE
Power
Supply
406 + 204
1 - 24 25 - 48
24 @ average 15.4 W each
and 24 @ 7.5 W each
or
36 @ average 15.4 W each
10 (bank 1) and 2 (bank 2) @
average 15.4 W each
19 (bank 1) and 4 (bank 2) @
average 7.5 W each
48 @ average 4.2 W each
External PoE
Power
Supply
(Failed
Internal PoE
Power
Supply)
204
(22 W is
reserved for
either ports
1-24 or 25-48)
10 (bank 1) and 2 (bank 2) @
average 15.4 W each
19 (bank 1) and 4 (bank 2) @
average 7.5 W each
48 @ average 4.2 W each
None
Summary of Contents for ProCurve 600
Page 1: ...Power over Ethernet HP ProCurve Power over Ethernet PoE PoE Planning and Implementation Guide ...
Page 2: ......
Page 3: ...Power over Ethernet PoE PoE Planning and Implementation Guide ...
Page 42: ......
Page 66: ......
Page 70: ......
Page 80: ......
Page 90: ......
Page 102: ......
Page 120: ......
Page 152: ......
Page 156: ......
Page 166: ......
Page 167: ......