Standard J8713A Configurations
Figure 10-14.Example of a 5412zl with two power supplies, J8713A
This configuration (Figure 10-14) is an example of two power supplies
supplying 900 watts each for a maximum of 1800 watts to a fully loaded chassis
of 288 ports. Therefore out of the total 288 available ports, 116 can be powered
at 15.4 watts each. That’s equal to a little over 4 modules, or all ports could be
used at 4.0 watts.
55 ports could be provisioned at 15.4 watts using 847 watts of the total 1800
leaving 953 watts. Then provision the other 238 ports at 4 watts using 952 watts
of the remaining 953 watts. Finally leaving 1 watt.
This configuration could be redundant for PoE power up to 900 W. The upper
6 slots would stay up if they were the ports suppling the PoE power and the
lower 6 slots were used for other than PoE power. One power supply has
enough power to supply system power to the upper 6 slots and keep the switch
up and running. And as long as the 900 watts of PoE power is not exceeded,
then the top 6 modules would remain powered.
Back
Front
900 watts
for PoE
900 watts
for PoE
Source of Power
Watts Available
# of Ports Powered and Average
watts/Port
Redundant # of Ports Powered and
Average watts/Port
Two Internal PoE
Power Supplies
(J8713A)
1800 (without
redundancy)
116 @ average 15.4 W each
240 @ average 7.5 W each
288 @ average 4.0 W each
None
Summary of Contents for ProCurve 600
Page 1: ...Power over Ethernet HP ProCurve Power over Ethernet PoE PoE Planning and Implementation Guide ...
Page 2: ......
Page 3: ...Power over Ethernet PoE PoE Planning and Implementation Guide ...
Page 42: ......
Page 66: ......
Page 70: ......
Page 80: ......
Page 90: ......
Page 102: ......
Page 120: ......
Page 152: ......
Page 156: ......
Page 166: ......
Page 167: ......