Configuring Port-Based and User-Based Access Control (802.1X)
How RADIUS/802.1X Authentication Affects VLAN Operation
If this temporary VLAN assignment causes the switch to disable a different
untagged static or dynamic VLAN configured on the port (as described in
the preceding bullet and in “Example of Untagged VLAN Assignment in a
RADIUS-Based Authentication Session” on page 12-70), the disabled
VLAN assignment is not advertised. When the authentication session
ends, the switch:
•
Removes the temporary untagged VLAN assignment and stops adver
tising it.
•
Re-activates and resumes advertising the temporarily disabled,
untagged VLAN assignment.
■
If you modify a VLAN ID configuration on a port during an 802.1X, MAC,
or Web authentication session, the changes do not take effect until the
session ends.
■
When a switch port is configured with RADIUS-based authentication to
accept multiple 802.1X and/or MAC or Web authentication client sessions,
all authenticated clients must use the same port-based, untagged VLAN
membership assigned for the earliest, currently active client session.
Therefore, on a port where one or more authenticated client sessions are
already running, all such clients are on the same untagged VLAN. If a
RADIUS server subsequently authenticates a new client, but attempts to
re-assign the port to a different, untagged VLAN than the one already in
use for the previously existing, authenticated client sessions, the connec
tion for the new client will fail.
Example of Untagged VLAN Assignment in a RADIUS-
Based Authentication Session
The following example shows how an untagged static VLAN is temporarily
assigned to a port for use during an 802.1X authentication session. In the
example, an 802.1X-aware client on port A2 has been authenticated by a
RADIUS server for access to VLAN 22. However, port A2 is not configured as
a member of VLAN 22 but as a member of untagged VLAN 33 as shown in
Figure 12-19.
12-70
Summary of Contents for PROCURVE 2910AL
Page 1: ...Access Security Guide ProCurve Switches W 14 03 2910al www procurve com ...
Page 2: ......
Page 3: ...HP ProCurve 2910al Switch February 2009 W 14 03 Access Security Guide ...
Page 84: ...Configuring Username and Password Security Front Panel Security 2 36 ...
Page 156: ...TACACS Authentication Operating Notes 4 30 ...
Page 288: ...Configuring Secure Socket Layer SSL Common Errors in SSL setup 8 22 ...
Page 416: ...Configuring Advanced Threat Protection Using the Instrumentation Monitor 10 28 ...
Page 572: ...Using Authorized IP Managers Operating Notes 14 14 ...
Page 592: ...12 Index ...
Page 593: ......