LOGLEVEL(
output-level
)
~ <numeric character> ((0-3)) <<2>>
Specifies the log output level.
0
Logs are not output. If
0
is specified, it is difficult to determine the cause of a
communication failure or an error that occurs during execution of a Business
Continuity Manager agent command.
1
Communication-related messages (
YKY300I
,
YKY301I
,
YKY304I
, and
YKY307I
)
are output.
2
In addition to the messages that are output when LOGLEVEL(1) is specified, both
the
YKY680I
and
YKY500I
messages are output. The
YKY680I
message is output
when an error occurs during an update request for a copy pair configuration or a
copy pair status. The
YKY500I
message displays the results of updated configuration
files.
3
In addition to the information output with LOGLEVEL(2), BCM logs are output.
The following table shows the
LOGLEVEL
specification and the messages that are
output.
Table 30 LOGLEVEL Specification and the Output Messages
Output messages
LOGLEVEL
No output
0
YKY300I
,
YKY301I
,
YKY304I
, and
YKY307I
1
YKY300I
,
YKY301I
,
YKY304I
,
YKY307I
,
YKY500I
, and
YKY680I
2
YKY300I, YKY301I, YKY304I, YKY307I, YKY500I, and
YKY680I
3
AUDITLOG(SYSLOG)
Specifies whether to output audit logs. When specified, the following additional information will
be output to
SYSLOG:
•
Name and return code of CLI commands that end with an error
•
Name and return code of CLI commands that end successfully (only for operational commands)
Audit logs are not output if the
AUDITLOG
parameter is not specified. If the
AUDITLOG
parameter
is specified, operations are performed as if
LOGLEVEL(2)
or later was specified.
MODE(startup-mode)
~({EDIT|MONITOR}) <<MONITOR>>
Specifies the permission level at which the Business Continuity Manager agent starts.
EDIT
– Allows definition, processing, and monitoring of copy groups.
MONITOR
– Allows monitoring of copy groups.
LOCK(lock-mode) ~ ({PREFIX|CHECK|NONE}) <<PREFIX>>
– Specifies the lock mode of the
configuration files. The
LOCK
parameter is valid only when
MODE(EDIT)
is specified. An error
occurs if the
LOCK
parameter is specified when
MODE(MONITOR)
is specified.
•
PREFIX
– Locks configuration files based on file name prefixes when the Business Continuity
Manager agent starts. Other users cannot update configuration files that are locked.
Creating Initialization Parameters
71