![HP P9000 Software Installation Manual Download Page 48](http://html.mh-extra.com/html/hp/p9000/p9000_software-installation-manual_155946048.webp)
If you change the dataset name when backing up the configuration files, make sure that you change
the prefix only.
The configuration files contain the copy group ID, DAD ID, route list ID, and path set ID. Therefore,
if you change the dataset name, the consistency between the files is lost, and then Business Continuity
Manager might become inoperable.
For details about configuration files, see the HP StorageWorks P9000 for Business Continuity
Manager Software Reference Guide.
Backing Up the Program Before Migration
Before migration, acquire a backup of the dataset where Business Continuity Manager will be
installed.
Pre-Upgrade Procedure
Deleting the User SVC
If you upgrade Business Continuity Manager versions earlier than 5.1 to Business Continuity
Manager 5.1 or later, you must delete the user SVC before you install the new version of Business
Continuity Manager.
If the user SVC was registered by using the
YKALCSVC
command, you can use the
YKALCSVC
command to delete the user SVC.
If the user SVC was registered by using the
IEASVC
xx parmlib member, you cannot use the
YKALCSVC
command to delete the user SVC. In this case, perform the procedure below.
To delete a user SVC that was registered by using the
IEASVC
xx parmlib member:
1.
Disable (comment out) the
SYMDEF
statement containing the
&YKSVCNO
system symbol in the
IEASYM
xx parmlib member.
/* SYMDEF(&YKSVCNO='SVC-number') */
2.
Disable (comment out) the
SVCPARM
statement containing the
JYUASVC
module in the
IEASYM
xx parmlib member.
/* SVCPARM SVC-number,REPLACE,TYPE(3),EPNAME(JYUASVC) */
3.
Perform re-IPL with the
CLPA
parameter specified.
For details on steps 1 and 2, see the MVS Initialization and Tuning Reference.
Removing the Concatenation of the Cataloged Procedures Library
Remove the dataset concatenation of the following library:
Library Name
DD Name
Cataloged procedures library HPQYPRCT
IEFPDSI
If you copied the HPQYPRCT library members to a user PROCLIB, delete the copied members.
Removing the Concatenation of the REXX Exec Library and the Libraries Used by ISPF Interface
Remove the dataset concatenation of the following libraries:
Library Name
DD Name
REXX Exec library
SYSEXEC
Panel library HPQYPNLT
ISPPLIB
48
Installing Business Continuity Manager