![HP P9000 Software Installation Manual Download Page 39](http://html.mh-extra.com/html/hp/p9000/p9000_software-installation-manual_155946039.webp)
YKLCNS2=
[
prefix2
] ~ <8 or fewer
alphanumeric characters>
Specify a
prefix2
for the license
information dataset so that the name of
the dataset is unique. If the
prefix2
is
omitted, specify
PARM='YKLCNS2='
.
For details about the
prefix2
for the
license information dataset, see section
“Naming Conventions for License
Information Datasets” (page 44)
.
LOGPUT
=[LOGR | SAM]
Specify whether or not the system logger service
is to be used, when outputting BCM logs.
The specified value for the
LOGPUT
parameter is
given priority over the
&YKLOGPT
system symbol
in the
IEASYMxx
parmlib member. If this
command is executed with the
LOGPUT
parameter
omitted (
PARM='LOGPUT='
is specified), the
value of the
&YKLOGPT
system symbol will be
used.
LOGR
: BCM logs are output using the system
logger service.
SAM
: BCM logs are output to sequential datasets.
SYSLOG
=[YES | NO]
Specify whether or not CLI command-execution logs
are output to SYSLOG.
The value specified for the
SYSLOG
parameter is
given priority over the
&YKSYSLG
system symbol in
the
IEASYMxx
parmlib member. If this command is
executed with the
SYSLOG
parameter omitted
(
PARM='SYSLOG='
is specified), the value of the
&YKSYSLG
system symbol will be used.
YES
: CLI command-execution logs are output to
SYSLOG.
NO
: CLI command-execution logs are not output to
SYSLOG.
For details about commands that collect CLI
command-execution logs, see the
Hitachi
Business Continuity Manager User Guide
.
Installing Business Continuity Manager
39