4.
Unmount the file systems and continue with the upgrade procedure.
Moving the Fusion Manager VIF to bond1
When the 9720 system is installed, the cluster network is moved to
bond1
. The 6.1 release requires
that the Fusion Manager VIF (Agile_Cluster_VIF) also be moved to
bond1
to enable access to ports
1234 and 9009. To move the Agile_Cluster_VIF to bond1, complete these steps:
1.
From the active Fusion Manager, list all passive management consoles, move them to
maintenance mode, and then unregister them from the agile configuration:
# ibrix_fm -f
nl
# ibrix_fm -m maintenance -A
nl
#
ibrix_fm -u <management_console_name>
2.
Define a new Agile_Cluster_VIF_DEV and the associated Agile_Cluster_VIF_IP.
3.
Change the Fusion Manager's local cluster address from
bond0
to
bond1
in the StoreAll
database:
a.
Change the previously defined Agile_Cluster_VIF_IP registration address. On the active
Fusion Manager, specify a new Agile _Cluster_VIF_IP on the
bond1
subnet:
ibrix_fm -t -I <new_Agile_Cluster_VIF_IP>
NOTE:
The
ibrix_fm -t
command is not documented, but can be used for this
operation.
b.
On each file serving node, edit the
/etc/ibrix/iadconf.xml
file:
vi /etc/ibrix/iadconf.xml
In the file, enter the new Agile_Cluster_VIF_IP address on the following line:
<property name=”fusionManagerPrimaryAddress”
value=”xxx.xxx.xxx.xxx’/>
4.
On the active Fusion Manager, re-register all backup management consoles using the
bond1
Local Cluster IP address for each node:
# ibrix_fm -R <management_console_name> -I <local_cluster_network_IP>
NOTE:
When registering a Fusion Manager, be sure the hostname specified with
-R
matches
the hostname of the server.
5.
Return the backup management consoles to passive mode:
# ibrix_fm -m passive
6.
Place the active Fusion Manager into maintenance mode to force it to fail over. (It can take
up to a minute for a passive Fusion Manager to take the active role.)
# ibrix_fm -m maintenance -A
7.
Unregister the original active Fusion Manager from the new active Fusion Manager:
# ibrix_fm -u <original_active_management_console_name>
8.
Re-register that Fusion Manager with the new values and then move it to passive mode:
# ibrix_fm -R <agileFM_name> -I <local_cluster_network_ip>
nl
# ibrix_fm -m passive
9.
Verify that all management consoles are registered properly on the
bond1
local cluster network:
# ibrix_fm -f
You should see all registered management consoles and their new local cluster IP addresses.
If an entry is incorrect, unregister that Fusion Manager and re-register it.
10. Reboot the file serving nodes.
184 Cascading Upgrades