HSG80 Array Controller V8.7 Maintenance and Service Guide
Replacement Procedures for BA370 Enclosure Elements
Figure 3–9: PVA module location
CAUTION: Carefully align the replacement PVA in the appropriate guide rails.
Misaligning the module might damage the backplane.
b.
Insert the replacement PVA and engage both retaining levers.
11. Press Enter/Return to resume device port activity and restart the “other
controller.”
NOTE: A controller restart is indicated by the temporary cycling of the port LEDs and a
F
LASHING
reset button.
IMPORTANT: If the “other controller” did not restart, press the “other controller” reset
button.
12. Enable failover and re-establish the dual-redundant configuration with one of the
following commands:
SET FAILOVER COPY=THIS_CONTROLLER
or
SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER
This command copies the subsystem configuration from “this controller” to the
“other controller.”
13. If desired, verify the failover configuration with the following command:
SHOW THIS_CONTROLLER FULL
14. Disconnect the PC or terminal from the controller maintenance port.