HSG80 Array Controller V8.7 Maintenance and Service Guide
2–19
Common Replacement Information and Procedures
On a HSx80 controller, press the port
button of the physical port containing
the disk device to be removed.
Press the Port button in for about 2
seconds and then release. When the
action is recognized by the controller, all
the port lights on the controller bulkhead
will flash on for about 1 second. The
port light on the controller will begin to
pulse.
REMEMBER TO PRESS THE
CORRECT PORT.
Wait for Port to quiesce.
Go to the side of cab from where you
will remove the drive and wait
approximately 10-15 seconds. The port
is quiesced, when all the disk devices
on that port show a flashing amber LED.
[NOTE: if a drive on that port has the
“LOCATE” light function enabled, the
drive LED for that device will be on
SOLID until the quiesce sequence is
over, at which time it will begin to flash
and the other devices will stop flashing.
Promptly - physically remove drive
about 1" out, then give drive time to
spin-down (60 seconds). Complete
removal process.
Both controllers port lights will remain
on and the disk device lights will go off.
Within about 20 seconds of device
removal, the device activity should
begin to resume on the remaining units.
The period of time is load dependent.
Installing disk device into slot.
Verify that 2 minutes have passed since
drive removal installation.
On HSx80 controller press the port
button of the physical port containing
the disk device to be removed.
Press the Port button in for about 2
seconds and then release. When the
action is recognized by the controller, all
the port lights on the controller bulkhead
will flash on for about 1 second. Then
the port light on the controller will begin
to pulse.
REMEMBER TO PRESS THE
CORRECT PORT.
CLI Commands to HSx80 or Actions
Comments