Cabling
Cabling guidelines
The cable colors in the cabling diagrams used in this chapter are for illustration purposes only.
Observe the following guidelines when working with server cables.
Before connecting cables
• Note the port labels on the PCA components. Not all these components are used by all servers:
◦
System board ports
◦
Drive and power supply backplane ports
◦
Expansion board ports (controllers, adapters, expanders, risers, and similar boards)
• Note the label near each cable connector. This label indicates the destination port for the cable connector.
• Some data cables are prebent. Do not unbend or manipulate the cables.
• To prevent mechanical damage or depositing oil that is present on your hands, and other contamination, do not touch
the ends of the connectors.
When connecting cables
• Before connecting a cable to a port, lay the cable in place to verify the length of the cable.
• Use the internal cable management features to properly route and secure the cables.
• When routing cables, be sure that the cables are not in a position where they can be pinched or crimped.
• Avoid tight bend radii to prevent damaging the internal wires of a power cord or a server cable. Never bend power
cords and server cables tight enough to cause a crease in the sheathing.
• Make sure that the excess length of cables is properly secured to avoid excess bends, interference issues, and airflow
restriction.
• To prevent component damage and potential signal interference, make sure that all cables are in their appropriate
routing position before installing a new component and before closing up the server after hardware installation/
maintenance.
When disconnecting cables
• Grip the body of the cable connector. Do not pull on the cable itself because this action can damage the internal wires
of the cable or the pins on the port.
• If a cable does not disconnect easily, check for any release latch that must be pressed to disconnect the cable.
Cabling
133
Summary of Contents for HPE ProLiant DL325
Page 24: ...Customer self repair 24 ...
Page 25: ...Customer self repair 25 ...
Page 26: ...Customer self repair 26 ...
Page 61: ... SFF a Remove the optical drive cage b Remove the blank Removal and replacement procedures 61 ...
Page 136: ... Slot 2 Slot 3 Cabling 136 ...
Page 139: ... Slot 2 Slot 3 Cabling 139 ...
Page 145: ... SFF Cable routing Power supply Non hot plug power supply Cabling 145 ...
Page 149: ...Cable routing Serial port Cabling 149 ...
Page 152: ... Slot 2 Slot 3 Cabling 152 ...