14
Figure 11 Installing a power supply
Installing an MPU and a switching fabric module
Installing an MPU
CAUTION:
The RUN LED flashes fast when the MPU is starting up. Do not install or remove the MPU during
this period to avoid hardware damage.
Before the installation, make sure the ejector levers of the MPU are outwards.
Slot 4 on the HSR6808 does not have a filler panel.
The installation procedures for the RSE-X2 and RSE-X3 MPUs are the same. The following example
uses the RSE-X2.
To install an MPU:
1.
Face the front of the router and locate the slot to be used.
2.
Loosen the captive screws with a Phillips screwdriver to remove the filler panel from the slot.
Keep the removed filler panel for future use.
Skip this step if you install the MPU to slot 4 of an HSR6808 router.
3.
Insert the MPU slowly along the slide rails until it makes close contact with the backplane, and
then push the ejector levers inward to lock the MPU in position.
4.
Use a Phillips screwdriver to fasten the captive screws on the two sides of the MPU.
For the MPU LED description, see "
MPU and switching fabric module LEDs
Figure 12 Installing an MPU
Installing an SFE-X1 switching fabric module
On the HSR6808, slot 6 must have an SFE-X1 switching fabric module installed.
Before the installation, make sure the ejector levers of the SFE-X1 are outwards.
To install an SFE-X1:
1.
Face the front of the router and locate the slot.