55
# Display the electrical label information about power monitor module 2.
<Sysname> display device manuinfo power-monitor 2
PowerMonitor 2:
DEVICE_NAME : HP FF 12500E Spare Pwr Monitor Mod JG804A
DEVICE_SERIAL_NUMBER : CN41GCB002
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2014-01-20
VENDOR_NAME : HP
•
In IRF mode:
# Display the electrical label information about power monitor module 2 on member switch 1.
<Sysname> display device manuinfo chassis 1 power-monitor 2
Chassis 1:
PowerMonitor 2:
DEVICE_NAME : HP FF 12500E Spare Pwr Monitor Mod JG804A
DEVICE_SERIAL_NUMBER : CN41GCB002
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2014-01-20
VENDOR_NAME : HP
Enabling power supply management
•
If power supply management is not enabled when you add a new card by inserting it into the slot
or starting power supply to the card by using the
power-supply
command, the system directly
powers on the card, and the power supply may become unstable or the system may restart because
of overloading.
•
If power supply management is enabled when you add a new card by inserting it into the slot or
starting power supply to the card by using the
power-supply
command, the system compares the
maximum power consumption of the card against the available power (including the redundant
power supply). If the former is not greater than the latter, the system supplies power to the card,
otherwise, the system does not supply power to the card.
To enable power supply management:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enable power supply
management.
•
In standalone mode:
power-supply policy enable
•
In IRF mode:
power-supply policy enable
chassis
chassis-number
Enabled by default.
Configuring the number of redundant power supplies
Redundant power supplies are reserved for power supply backup and power supply threshold alarming.
With multiple redundant power supplies configured in the system, if a power supply fails or the system
power supply is overloaded, the system automatically enables a redundant power supply. As a result, the
number of redundant power supplies decreases by one.